introduction

Metal shielding power cable

Security code: No
browse:
add time: 2016-11-04 15:11:17
recommendation:

Buy join the shopping cart

A, use the product
Is suitable for rated voltage up to and including 0.6/1 kv power line for delivery of electricity.This product has strong resistance to electromagnetic interference, resistance to lightning and uniform electric field, and improve the characteristics of the power supply quality, especially for places with precision electronic devices, such as the computer center, the monitoring center of aeronautics and astronautics, intelligent building, etc.
Second, the standards
This product is designed and manufactured according to Q/HX - 15
Third, the model name

modelThe product name
Copper coreAluminum conductor
VV-P
YJV-P
VLV-P
YJLV-P
Polyvinyl chloride (cross-linked polyethylene) insulated metal shield PVC sheathed power cable
VV22-P
YJV22-P
VLV22-P
YJLV22-P
Polyvinyl chloride (cross-linked polyethylene) insulated metal BingBiGang with armored PVC sheathed power cable
VV32-P
YJV32-P
VLV32-P
YJLV32-P
Polyvinyl chloride (cross-linked polyethylene) insulated metal mask fine steel wire armored PVC sheathed power cable
ZR-VV-P
ZR-YJV-P
ZR-VLV-P
ZR-YJLV-P
Flame retardant PVC (cross-linked polyethylene) insulated metal shielding sheathed power cable
ZR-VV22-P
ZR-YJV22-P
ZR-VLV22-P
ZR-YJLV22-P
Flame retardant PVC (cross-linked polyethylene) insulated metal BingBiGang with armored PVC sheathed power cable
ZR-VV32-P
ZR-YJV32-P
ZR-VLV32-P
ZR-YJLV32-P
Flame retardant PVC (cross-linked polyethylene) insulated metal mask fine steel wire armored PVC sheathed power cable
NH-VV-P
NH-YJV-P
-Polyvinyl chloride (cross-linked polyethylene) insulated metal shield PVC sheathed fire-resistant power cable
NH-VV22-P
NH-YJV22-P
-Polyvinyl chloride (cross-linked polyethylene) insulated metal BingBiGang with armored PVC sheathed fire-resistant power cable
NH-VV32-P
NH-YJV32-P
-Polyvinyl chloride (cross-linked polyethylene) insulated metal mask fine steel wire armored PVC sheathed fire-resistant power cable

Type: the metal shield of power cable is on the design structure and cross-linked polyethylene insulating power cable and PVC insulated power cable is different, on the model with a distinction between "-p" suffix, such as: v. v. - P, YJV - P, YJLV22 - P and so on.
Fourth, specifications

Type no.Number of coresNominal cross section
(mm2)
Copper coreAluminum conductor
VV-P、YJV-P
ZR-VV-P、ZR-YJV-P
NH-VV-P、NH-YJV-P
VLV-P、YJLV-P
ZR-VLV-P、ZR-YJLV-P
14-300
VV-P、YJV-P
ZR-VV-P、ZR-YJV-P
NH-VV-P、NH-YJV-P
VLV-P、YJLV-P
ZR-VLV-P、ZR-YJLV-P
24-185
VV22-P
ZR-VV22-P、ZR-YJV22-P
ZR-VV32-P、ZR-YJV32-P
ZR-VV42-P、ZR-YJV42-P
VLV22-P
ZR-VLV22-P、ZR-YJLV22-P
ZR-VLV32-P、ZR-YJLV32-P
ZR-VLV42-P、ZR-YJLV42-P
24-185
VV-P、YJV-P
ZR-VV-P、ZR-YJV-P
NH-VV-P、NH-YJV-P
VLV-P、YJLV-P
ZR-VLV-P、ZR-YJLV-P
32.5 ~ 240
VV22-P
ZR-VV22-P、ZR-YJV22-P
ZR-VV32-P、ZR-YJV32-P
ZR-VV42-P、ZR-YJV42-P
VLV22-P
ZR-VLV22-P、ZR-YJLV22-P
ZR-VLV32-P、ZR-YJLV32-P
ZR-VLV42-P、ZR-YJLV42-P
32.5 ~ 240
VV-P、YJV-P
ZR-VV-P、ZR-YJV-P
NH-VV-P、NH-YJV-P
VLV-P、YJLV-P
ZR-VLV-P、ZR-YJLV-P
3 + 14-240
VV22-P
ZR-VV22-P、ZR-YJV22-P
ZR-VV32-P、ZR-YJV32-P
ZR-VV42-P、ZR-YJV42-P
VLV22-P
ZR-VLV22-P、ZR-YJLV22-P
ZR-VLV32-P、ZR-YJLV32-P
ZR-VLV42-P、ZR-YJLV42-P
3 + 14-240
VV-P、YJV-P
ZR-VV-P、ZR-YJV-P
NH-VV-P、NH-YJV-P
VLV-P、YJLV-P
ZR-VLV-P、ZR-YJLV-P
44-185
VV22-P、ZR-VV22-P
ZR-YJV22-P、ZR-VV32-P
ZR-YJV32-P、ZR-VV42-P
ZR-YJV42-P、NH-VV22-P
NH-YJV22-P、NH-VV32-P
NH-YJV32-P、NH-VV42-P
NH-YJV42-P
VLV22-P
ZR-VLV22-P、ZR-YJLV22-P
ZR-VLV32-P、ZR-YJLV32-P
ZR-VLV42-P、ZR-YJLV42-P
44-185

Five, the conditions of use
1, cable conductor long-term working temperature shall not exceed 70 ℃
2, short circuit, cable conductor of the highest temperature should not exceed 160 ℃
3, when laying the environment temperature is not lower than 0 ℃, lower than 0 ℃ should be in advance when heating cable laying, the minimum bending radius
4, single core cable should not less than 20 times of cable diameter
More than 5, cable is not less than 15 times of cable diameter
6, laying, on both ends of the shield should be reliable grounding, does not make the shield broken or loose, otherwise it will reduce the shielding effect