微信营销
欢迎关注浦光仪表微信公共帐号
1扫描以上二维码2加微信号:

Mail| Chinese| English|Map|Disclaimer

introduction

introduction

Flame retardant computer cable

Security code: No
browse:
add time: 2016-11-04 14:09:23
recommendation:

Buy join the shopping cart

A, intrinsically safe circuit using computer shielded cable

Product characteristics and USES: this product low capacitance, low inductance, excellent shielding performance and anti-interference performance, special high temperature type computer cable fluoride and fluorine plastic imported material such as rubber, can be used in medium and long term - 40-260 ℃ environment, the product has no secondary superior water, acid and alkali resistant properties, cable structure designed for safety explosion-proof circuit design, not only for bridge laying, and can be used for cable laying and directly buried installation.Suitable for the explosion protection requirements and other harsh environments and distributing system, automatic detection system for transmission line, explosion-proof safety performance is significantly higher than general DCS cable and computer control cable.

Features: ac rated voltage: 300/500 kv

The highest working temperature: polyethylene insulation does not exceed 70 ℃;Cross-linked polyethylene insulation 90 ℃;Computer characteristics of low smoke zero halogen cable for low smoke zero halogen flame retardant polyolefin 70 ℃;Low smoke zero halogen flame retardant crosslinked polyolefin 90 ℃ and 125 ℃ of two;Fep (F46) insulation does not exceed 200 ℃;Import soluble polytetrafluoroethylene (PFA) does not exceed 260 ℃.

Minimum ambient temperature: PVC sheathed: fixed installation to 40 ℃, the fixed installation - 15 ℃;Fluorine plastic and silicone rubber sheath: fixed installation - 60 ℃, the fixed installation to 25 ℃.

The basic model and name:

ia-DJYPV?P、ia-DJYP2V?P2、ia-DJYP3V?P3、ia-DJYJPV?P、ia-DJYJP2V?P2、ia-DJYJP3V?P3、ia-DJYDPYD?P、ia-DJYDP2YD?P2、ia-DJYDP3YD?P3、ia-DJF46PVP、、ia-DJF46PVRP、ia-DJF46GPG、ia-DJF46GPGR、ia-DJF4F46P-2、ia-DJF4F46P2-2;

Note: IA said intrinsically safe electronic computer, the DJ said low smoke zero halogen, D, G, said F46 fluorine plastic, silicone rubber, F said P said block or total shielding, P2 said copper tape around the package, aluminum-plastic composite belt winding and P3 said, Y said polyolefin insulation and sheath, V PVC, flame retardant cable and ZR in front of the model computer, flame retardant cable, armored cable model after 22, basic models as above.

Production range: logarithmic * nominal group to wring some section (was) :

(1, 2, 3, 4, 5, 6, 7, 10, 12) * 2 * (0.5, 0.75, 1.0, 0.75, 1.0);14 * 2 * 0.5;

(1, 2, 3, 4, 5, 7, 10) x 3 x (0.5, 0.75, 1.0, 0.75, 1.0).

Second, low smoke zero halogen flame retardant computer cable

Usage: this cable has low pressure low capacitance and inductance, and shielding performance and good anti-jamming performance, thus explosion-proof performance is better than that of general computer cables and control cables. It is suitable for the explosion-proof requirement of distributed systems and automated detection control requirement for low smoke zero halogen flame retardant circuit transmission line.

Using features: rated voltage U0 / U: 300/500 v.The highest working temperature: polyethylene insulation does not exceed 70 ℃, cross-linked polyethylene insulation does not exceed 90 ℃, irradiation crosslinking polyethylene insulation does not exceed 105 ℃;Minimum ambient temperature: fixed installation to 40 ℃, the fixed installation - 15 ℃;The minimum bending radius: no armoured cable should be not less than 6 times of cable diameter;With armored cable should be not less than 12 times of overall diameter ℃.

The product name and type:

WZR-DJYPE、WZR-DJYPE22、WZR-DJYPE32、WZR-DJYPEP、WZR-DJYP2E、WZR-DJYP2EP2、WZR-DJYP3E、WZR-DJYP3EA53、WZR-DJYJPE、WZR-DJYJPE22、WZR-DJYJPE32、WZR-DJYJPEP、WZR-DJYJP2E、WZR-DJYJP2EP2、WZR-DJYJP3E、WZR-DJYJP3EA53、WZR-DJFYJPE、WZR-DJFYJPE22、WZR-DJFYJPE32、WZR-DJFYJPEP、WZR-DJFYJP2E、WZR-DJFYJP2EP2、WZR-DJFYJP3E、WZR-DJFYJPEA53.

Note: W said low smoke zero halogen flame retardant, ZR said, the DJ said to wring, E said polyolefin sheath, 22, said steel tape armoured, 32, said fine steel wire armoured and 53 said monolayer steel belt longitudinal armoring, Mr Wen said Y polyethylene insulation, J said crosslinking polyethylene insulation, F said irradiation crosslinking polyethylene insulation, P said copper wire braided shielding, P2 said copper tape screened copper tape around the package, P3 said aluminum foil/plastic composite belt shielding.

Production range: logarithmic by each pair of some x = nominal section

(1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 12, 14, 16, 19, 24) x 2 x (0.75, 1.0, 1.5);

(1, 3, 4, 5, 6, 7, 8, 10, 12, 14) x 3 x (0.75, 1.0, 1.5).

Three computer cable, flame retardant

For power generation, metallurgy, petrochemical and other industrial and mining enterprises and distributing system, computer system, signal transmission of the automation system and testing instruments, meters and other connection with multiple of shielded cable.

Using features: working temperature: generally does not exceed 70 ℃.Minimum ambient temperature: fixed installation - 40 ℃.The fixed installation to 15 ℃.General flame retardant properties conform to the stipulations of the GB12666.2-90;Into a bunch of flame retardant performance in line with the GB - 12666.5-90;The rated voltage U0 / U: 300/500 v.The minimum bending radius: no armoured layer cable should be not less than 10 times of cable diameter;Have armored cable should be not less than 12 times of cable diameter.

Model and name:

ZR-DJYPV、ZR-DJYPV/SA、ZR-DJYPV22、ZR-DJYPV22/SA、ZR-DJYPV32、ZR-DJYPV32/SA、ZR-DJYPVP、ZR-DJYPVP/SA、ZR-DJYP2V、ZR-DJYP2V/SA、ZR-DJYP2VP2、ZR-DJYP2VP2/SA、ZR-DJYP3V、ZR-DJYP3V/SA、ZR-DJYP3VP3、ZR-DJYP3VP3/SA、ZR-DJYP3VA53、ZR-DJYP3VA53、DZR-DJYPV、DZR-DJYPV22、DZR-DJYPV32、DZR-DJYPVP、DZR-DJYP2V、DZR-DJYP2VP2、DZR-DJYP3V、DZR-DJYP3VP3、DZR-DJYP3VA53.

Note: D said to wring, ZR said flame retardant, SA said of bundles, V polyvinyl chloride (PVC), 22, said steel tape armoured, 32, said fine steel wire armoured and 53 said monolayer steel belt longitudinal armoring, Mr Wen said, J said crosslinking, F Y said irradiation crosslinking, shielding, P2 P said said copper tape screened copper tape around the package, P3 said aluminum foil/plastic composite belt shielding.

Production range: logarithmic by each pair of some x = nominal section

(1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 12, 14, 16, 19, 24) x 2 x (0.75, 1.0, 1.5);

(1, 3, 4, 5, 6, 7, 8, 10, 12, 14) x 3 x (0.75, 1.0, 1.5).

Four, high temperature resistant, anti-corrosion, oil resistant computer cable

Apply to power generation, metallurgy, petrochemical and other industrial and mining enterprises, high temperature occasion distribution system, computer system, signal transmission of the automation system and testing instruments, meters and other connected with multiple shielded cable.

Using features: rated voltage: 300/500 v.Working temperature: F46 fluorine plastic insulation does not exceed 200 ℃;F4 fluorine plastic insulation does not exceed 260 ℃;F47 fluorine plastic insulation does not exceed 285 ℃;Silicone rubber insulation does not exceed 180 ℃.

Model: JFF, JFFP2, JFFP - 1, 2, JGGP, JFGP JFFP -, JGVFP.

DJF4H11、DJF4HP2、DJF4HP-1、DJF4HP-2、DJYF4H11、DJYF4H11P2、DJYF4H11P-1、DJF4H11P-2、DJF4GP、DJF47H9、DJF47H9P2、DJF47H9P-1、DJF47H9P-2、DJYF47H9、DJF47H9P2、DJF47H9P-1、DJF47H9P-2、DJF47GP.

Note: J said to wring, V nitrile sheath, G the silicon rubber insulation, F F46 copper wire shielding, insulation, P said P2 said copper tape screened or copper tape around the package, P3 said aluminum foil/plastic composite belt shielding.

Production specification: logarithmic * nominal each pair of some cross section:

(1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 12, 14, 16, 19, 24) x 2 x (0.75, 1.0, 1.5);

(1, 3, 4, 5, 6, 7, 8, 10, 12, 14) x 3 x (0.75, 1.0, 1.5)


on aHigh temperature resistant computer cable
nextno
bottom.jpg
  • fax:021-51685578
  • mail:info@puguang.com
  • address:Zhabei District, Haining, Shanghai Road, No. 899, Changtai enterprise World Plaza, A building, 22 floors
link:BaiduSougou