Copper heat resistance WZC - 035 as measure temperature sensor, and display meter, recording meter and electronic regulator usually used.It can directly measure all kinds of production process from 200 ℃ ~ 420 ℃ in the scope of liquid, steam and gas medium, as well as the surface temperature of the solid.
Technical parameters:
1), copper heat resistance, WZC WZC - 200-201 model parameters
model | Degree, | Type of installation | Protecting tube material | Measuring range | D | S | d |
WZC-200 | Cu50 | Pipe thread G1/2, | 1Cr18NiTi | - 50 ~ 100 ℃ | 34 | 27 | 12 |
WZC-201 | Cu50 | Thread M27X2 | 1Cr18Ni9Ti | - 50 ~ 100 ℃ | 40 | 32 | 12 |
2), copper heat resistance WZP - 200, WZP - 201 parameters
model | Degree, | Type of installation | Protecting tube material | Measuring range | D | S | d |
WZP-200 | Pt100 | Pipe thread G1/2, | 1Cr18NiTi | - 50 ~ 100 ℃ | 34 | 27 | 12 |
WZP-201 | Pt100 | Thread M27X2 | 1Cr18Ni9Ti | - 50 ~ 100 ℃ | 40 | 32 | 12 |
3), copper heat resistance sensor length codes and specifications series of size
Code name specifications | 1 | 2 | 3 | 4 | 5 | 6 | 7 | 8 | 9 | 10 | F |
L1 (deep) mm | 100 | 150 | 200 | 250 | 260 | 300 | 340 | 360 | 400 | 450 | other |
L2 (general) mm | 550 | 600 | 650 | 700 | 710 | 750 | 790 | 810 | 850 | 900 | other |
1, the national standards for WZC - 200 contains the G1/2, M27X2 two threads.I plant for selection for pipe thread G1/2.Finalize the design for WZC - 200, the common thread M27X2 styling for WZC - 201.
2, copper heat resistance is not in the length, please indicate the size of the requirement.
One end is separate 3, A, B, C and even.
4, for example, WZC - 200-2: said Cu50 sensors, threaded G1/2, insert depth of 150 mm long, 550 mm.12 mm in diameter.
5, such as WZP - 01-3: said Pt100 sensors, thread M27 x 2, insert depth of 200 mm long, 550 mm.12 mm in diameter.