Bimetallic thermometer features
The scene display temperature, intuitive and convenient
Safe and reliable, long service life
Many kinds of structure forms, can meet different requirements
The working principle of
Bimetallic thermometer is based on the ring around the made of bent bimetallic strip.End is heated expands, turns the pointer, the instrument will show thermoelectric potential should value.
Main technical parameters of bimetallic thermometer
Execution standard: JB/T8803-1998;GB3836-83.
Dial nominal diameter: 60, 100, 150
Precision level: 1.0, 1.5
Thermal response time: 40 s or less
Protection grade: IP55
Angle adjustment error: error Angle adjustment shall not exceed 1.0% of its range
Back to the poor: double metal thermometer should be no greater than the absolute value of basic error limits.
Repeatability: the thermometer repeatability limit scope shall not cut more than 1/2 basic error limits the absolute value of.
Bimetallic thermometer temperature measurement range
℃ temperature range | To adapt to the scope of | |
Industrial, commercial, | Laboratory and small | |
+ 40-80 - | Square root | Square root |
+ 80-40 - | Square root | Square root |
0 to 50 | Square root | Square root |
0-100. | Square root | Square root |
0-150. | Square root | Square root |
0-200. | Square root | Square root |
0-300. | Square root | Square root |
0-400. | Square root | Square root |
0-500. | Square root | Square root |
The bimetallic thermometer work normal atmospheric conditions
The workplace | Temperature ℃ | Relative humidity % |
shelter | - 25 + 25 | 5-100. |
Outdoor place | + 85-40 - | 5-100. |
Bimetallic thermometer form
Overall dimensions
In the form of | A | B | C | E | L | D |
The axial type | 65 | 23 | 73 | - | 75 100 150 200 300 400 500 750 1000 | Φ 6 Φ 8 Φ 10 |
105 | 23 | 73 | - | |||
155 | 23 | 73 | - | |||
The radial type | 65 | 50 | 110 | 34 | ||
105 | 50 | 110 | 34 | |||
155 | 50 | 110 | 34 | |||
135 ° to type | 105 | 23 | 85 | - | ||
155 | 23 | 85 | - | |||
Universal type | 105 | 23 | 178 | 120 | ||
155 | 23 | 178 | 120 |
naming
model | instructions | ||||||||
W | Code name | The temperature instrument | |||||||
S | Metal expansion type | ||||||||
S | Bimetallic strip thermal components | ||||||||
X | Electric contact structure | ||||||||
3 | Watchcase nominal diameter | 60 | |||||||
4 | 100 | ||||||||
5 | 150 | ||||||||
0 | Location features | The axial (straight) | |||||||
1 | The radial (Angle) | ||||||||
2 | To (obtuse Angle 135 °) | ||||||||
8 | Universal (adjustable Angle) | ||||||||
0 | Install the fixed form | No fixed device | |||||||
1 | Movable external thread | ||||||||
2 | Movable internal thread | ||||||||
3 | Fixed screw thread | ||||||||
4 | Fixed flange | ||||||||
5 | Card sets of thread | ||||||||
6 | Card flange | ||||||||
There is no | Form of protection | ordinary | |||||||
W | protected | ||||||||
F | Anti-corrosion type | ||||||||
M | Electric contact type adjustment | Upper and lower | |||||||
W | Double limit | ||||||||
F | Double threshold | ||||||||
B | Flame-proof type | Flame-proof type bimetal |