微信营销
欢迎关注浦光仪表微信公共帐号
1扫描以上二维码2加微信号:

Mail| Chinese| English|Map|Disclaimer

introduction

introduction

W100 temperature sensor

Security code: No
browse:
add time: 2016-11-08 15:12:55
recommendation:

Buy join the shopping cart

1. The index number and measurement range
(1) heat resistance (t is the absolute value of the measured temperature, ℃.)
Thermal resistance categoryTemperature measurement rangePrecision gradeAllowable deviation
Cu- 50 ~ + 100
±(0.30+0.006) |t|
Pt- 200 ~ + 500A grade±(0.15+0.002) |t|
Class B±(0.30+0.005) |t|
2. Thermocouple (t for actual temperature, allowing the temperature degrees are available, and also can use the percentage of actual temperature, said taking large amounts.)
Degree,Tolerance level
Tolerance values℃ temperature rangeTolerance values℃ temperature range
KPlus or minus 1.5 ℃- 40 ~ + 375Plus or minus 2.5 ℃- 40 ~ + 333
±0.004|t|375 ~ 1000±0.0075|t|333 ~ 1200
EPlus or minus 1.5 ℃- 40 ~ + 375Plus or minus 2.5 ℃- 40 ~ + 333
±0.004|t|375 ~ 800±0.0075|t|333 ~ 900
S+ / - 1 ℃0 ~ + 1100Plus or minus 1.5 ℃0 ~ 600
±[1+0.003(t-1100)]1100 ~ 1600±0.0025|t|600 ~ 1600
B----
--±0.0025|t|600 ~ 1700
2. Normal temperature insulation resistance
(1) thermal resistance
Thermal resistance at ambient temperature for 15 ~ 35 ℃, relative humidity is not more than 80%, test voltage is 10 ~ 100 v (dc) electrode and outer casing of the insulation resistance between 100 m Ω or higher.
2 thermocouple
Thermocouple in the environmental temperature is 20 + 15 ℃, relative humidity is not more than 80%, the test voltage for 500 + 50 v (dc) electrode and outer casing of the insulation resistance between 100 m Ω or higher.
3. The thermal response time
When the temperature appear step change, the instrument of current output signal changes to correspond to the step change of 50% of the time required, usually expressed as a tau 0.5, in general, tau 0.5 90 s or less.
4. The minimum in depth
Minimum in depth of not less than 50 mm.
5. Nominal pressure
Generally refers to the protection tube at room temperature by static external pressure and not broken, take 1.5 times the nominal pressure test pressure.Allows working pressure is not only related to protecting tube material, diameter, wall thickness, and structural forms, installation methods, inserting depth, and the temperature of the measured medium, flow velocity and variety.
Instrument typesinstructions
W100/□/□/□/□/□/□/□/□/□/□
Temperature sensing element typeZ








The thermal resistance
Rthermocouple
Temperature sensing element materialP1Pt100
P2Pt1000
C1Cu50
C2Cu100
KK type thermocouple (nickel chrome - nickel silicon)
EE type thermocouple (nickel chrome - constantan)
SS type thermocouple (platinum rhodium 10 - platinum)
BB type thermocouple (30 - platinum rhodium platinum rhodium 6)
RR type thermocouple (platinum rhodium 13 - platinum)
NN type thermocouple (nickel chrome - nickel silicon silicon magnesium)
JJ type thermocouple (iron - constantan)
TT copper-constantan thermocouples,)
The instrument typeOThe assembling
KArmor type
MWear resistant
DEnd face type
LRight Angle bend type
WMicro type
HType of health
Structure formSSingle type
TThe double only
Precision gradeAMeaning see technical characteristics in detail
B
The output formU(RTD) only the thermal resistance
V(mV) only the thermocouple
The connection method01Without a fixed device type
02Fixed screw type
03Activity card set screw type
04Fixed flange
05Activity card flange type
06Conical protection tube fixed screw type
07Rectangular flange
The cold end form1Simple type (compensation conductor)
2The bop wiring box
3Waterproof connector box
4Explosion-proof wiring box
5The connector type
Protecting tube diameterMetal protection tubeM0Phi is 16
M1Phi 20
M2Phi 10
M3Phi 8
M4Phi 12
Non-metallic protection tubeN0Phi is 16
N1Phi 25 (double)
N2Phi 20
N3Phi (double layer or three layer 33)
otherO5Other diameter (user-specified)
Insert depth-XXXLength (user-specified)
Selection, for example: W1010 - m0 ZP1OSBU - 023-023
W10 type temperature sensor assembly, Pt100 temperature sensing element for thermal resistance, B level precision, fixed screw thread connection, 16 stainless steel protecting tube diameter, waterproof connector, the inserting depth of 150 mm.


on ano
nextW101 temperature transmitter
bottom.jpg
  • fax:021-51685578
  • mail:info@puguang.com
  • address:Zhabei District, Haining, Shanghai Road, No. 899, Changtai enterprise World Plaza, A building, 22 floors
link:BaiduSougou