Seismic electric contact pressure gauge product application: widely used in mechanical, chemical, petroleum, metallurgy, electric power and other industrial production processes.
Environmental conditions of use: use the working temperature: - 25 ℃ ~ 55 ℃
Maximum working pressure: no greater than 2/3 of the upper limit value of the instrument
Work environment vibration frequency is not more than 25 hz, the amplitude is not greater than 0.5 mm
Temperature: 25 ℃ ~ 55 ℃
Seismic electric contact pressure gauge technical parameters:
model | YNXC-100ZQ-Z | YNXC-150ZQ-Z | YNXC-100-Z | YNXC-150-Z | YNXC-100NQ-Z | YNXC-150NQ-Z | |
Structure form | The axial belt in front of | Radial infinite | The radial with the front | ||||
Measuring range MPa | - 0.1-0.15;- 0.1-0.3;- 0.1-0.5;- 0.1-0.9;- 0.1-1.5;- 0.1-2.4 0-0.25;0-0.4;0-0.6;0-1.0;0-1.6;0-2.5;0-4.0;0-6.0;0 to 10;0 to 16;0 to 25;0 to 40;0-60 | ||||||
Accuracy % | + / - 1.6 | ||||||
Contact electrical parameters | Working voltage | 380VAC;220VDC | |||||
Maximum working current | 1A | ||||||
Sustained current | 0.6A | ||||||
The most powerful (non inductive load) | 20VA | ||||||
The connector | X14K4P | Waterproof connector | X14K4P | Waterproof connector | X14K4P |
Working temperature of use: 25 ℃ ~ 55 ℃
Maximum working pressure: no greater than 2/3 of the upper limit value of the instrument
Work environment vibration frequency is not more than 25 hz, the amplitude is not greater than 0.5 mm
Instrument standards: Q / 320211 DGH05-2004
Seismic electric contact pressure gauge shape size:
The use and ordering information:
Instrument working environment should be no corrosive gas.
Please state the name of order, model and measurement range.
Low voltage large current time with the company produced YXC type protection relay.