introduction

introduction

601/602 series inductance type liquid level transmitter

Security code: No
browse:
add time: 2016-11-08 14:24:23
recommendation:

Buy join the shopping cart

601/602 series of liquid level transmitter is our factory introduction of foreign similar products technology development of radio frequency induction type liquid level meter.Its various level changes of the parameters can be converted into a standard current signal, remote transmission to the operating room, for secondary instrument or computer for centralized display, alarm, or automatic control.Its good structure and installation, can be used in high temperature and high pressure, strong corrosion, easy to crystallization, prevent jams, prevent cold junction and under special conditions, such as solid powder, granular material level, material level or the level of continuous testing, which can be widely applied in all kinds of industrial process control testing.

There were features simple structure: move or elastic element, so stay on sex is extremely high, little maintenance.
Convenient installation: the built-in type structure especially shows the characteristics, without any special tools.
Convenient adjustment: the zero and span two potentiometer can be zero within the scope of the liquid level detection effectively any migration or range change, two adjustment each other.
Wide range of USES: applicable to high temperature and high pressure, strong corrosive medium level measurement.

The main technical indicators effective detection range: 0-0.2-20 m
Essence: 0.5, 1, 1.5 on the Richter scale are unlikely
Pressure range: negative pressure, normal pressure and high pressure (below 32 mpa)
Working temperature: - 50 ~ 240 ℃
Ambient temperature: - 20 ~ 75 ℃
Applicable medium: acid, alkali, salt, or any of ptfe non-corrosive medium
Output signals: 4-20 ma, two wire
Power supply: load resistance 0-750 Ω DC24V
Fixed way: thread M20 x 1.5, M27 x 2 flange installation DN15, DN25, (, DN80.
Scene shows: analog display 0-100%, digital display, depth of field
Mixer selection way

Type spectrumSaid Ming
60

Class quality,1
Sink into the cable type liquid level transmitter
2
Insert stem type liquid level transmitter
Transmitter typeG
standard
D
Flameproof (Exd Ⅱ CT6 1 area including acetylene)
I
The Ann model (Exd Ⅱ CT4 1 area)
The process connection typeT
External thread connecting pipe M20 x 1.5
F
Flange (0.6 MPa GP9119.6 PN - 88
E
Flange DN100 PN 0.6 MPa GP9119.6-88
S
M27 x 2 male
Y
The special requirements of contract
Containment requirements4
Strong corrosion resistance
8
Resistance to crystallization
Indicating meterM1
Pointer to the header
M2
Digital display meter
Precision grade02
0.5%
05
1%
07
1.5%

-□
The line length (mm)

-□
Liquid level range (mm)