微信营销
欢迎关注浦光仪表微信公共帐号
1扫描以上二维码2加微信号:

Mail| Chinese| English|Map|Disclaimer

introduction

introduction

High-temperature thermocouple compensating conductor

Security code: No
browse:
add time: 2016-11-04 17:24:49
recommendation:

Buy join the shopping cart

1, use:
Thermocouple with high-temperature thermocouple cable, compensation cable, is in a certain temperature range (including high temperature and normal temperature) to match the nominal value of the same pair of thermoelectric emf with insulation wire, use them to connect the thermocouple and measuring devices, to compensate for them with the error produced by the temperature change of the thermocouple junction.This product is suitable for the index number is S, E, T, K, J, N type thermocouple and temperature display instrument between the electrical connection, in order to improve the accuracy of measurement.
2: the conditions of use:
High: (1) working temperature: heat with 200 ℃ and 260 ℃ of two;
General use: up to 70 ℃ and 105 ℃.
(2) the lowest temperature: fluorine plastic insulated and sheathed cable: fixed installation - 60 ℃, the fixed installation - 20 ℃;
PVC insulated and sheathed cable: fixed installation to 40 ℃, the fixed installation to 15 ℃.
(3) the minimum bending radius: PVC insulated and sheathed cable of armored cable is not less than 6 times of cable diameter, fluorine plastic insulation and sheath of armored cable should not less than 10 times of cable diameter, armored cable should not less than 12 times of cable diameter.
3, product varieties, specifications, and structure
(1) product varieties and models: see table 1
Table 1
The product name
Type no.
With thermocouple
Thermocouple index number
Copper, copper nickel compensation type wire (cable)
SC
10 - platinum platinum rhodium thermocouple
13 - platinum rhodium platinum thermocouple
S
Iron - copper and nickel compensation wire (cable)
Copper, copper nickel compensation type wire (cable)
KCA
KCB
Nickel chrome - nickel silicon thermocouple
K
Nickel chrome - nickel silicon extension wire (cable)
KX
Nickel chrome - nickel silicon thermocouple
K
Iron - copper and nickel compensation wire (cable)
Silicon nickel chrome - nickel silicon extension type wire (cable)
NC
NX
Nickel chromium silicon - nickel silicon thermocouple
N
Copper nickel chrome - nickel extended type wire (cable)
EX
Copper nickel chrome - nickel thermocouple
E
Iron - copper and nickel extension wire (cable)
JX
Iron, copper and nickel thermocouple
J
Copper, copper nickel extended type wire (cable)
TX
Nickel copper-constantan thermocouple
T
(2) product specification: see table 2
Table 2.

The name says
Conductor was nominal section
The conductor structure mm
Compensation conductor
Compensating cables
A
B
Wire core logarithm
1
Two quad: 1 ~ 24
Three fields: 1 ~ 19
0.5
1 / Φ 0.80
7 / Φ 0.30
1.0
1 / Φ 1.13
7 / Φ 0.43
1.5
1 / Φ 1.37
7 / Φ 0.52
2.5
1 / Φ 1.76
19 / Φ 0.41
Note: (1) compensation wire specifications: 2 * conductor nominal section, compensation cable specifications for: some * 2 * conductor nominal section, line to recommend
Is: 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 12, 14, 16, 19, 24, etc.
(2) according to the requirements of users can provide flame retardant, fire-resistant, low smoke low halogen, low smoke zero halogen type compensation cable and silicon rubber insulation and heat compensation cable sheath.When you order it should mark.
4, technical requirements
Alloy wire (1) compensation and compensation cable conductor and insulation layer color: as shown in table 3
Table 3
Product model
Compensation wire and cable core
Insulating layer coloring
With thermocouple
Degree,
The anode
The cathode
The anode
The cathode
SC
copper
Copper and nickel 0.6
red
green
S (platinum rhodium 10 - platinum)
R (platinum rhodium 13 - platinum)
KCA
iron
Copper and nickel 22
red
blue
K (nickel chrome - nickel silicon)
KCB
copper
Copper and nickel 40
red
blue
KX
Nickel chrome 10
Nickel and silicon
red
black
EX
Nickel chrome 10
Copper and nickel 45
red
brown
E (copper nickel chrome - nickel)
JX
iron
Copper and nickel 45
red
The purple
J (iron - copper and nickel)
TX
copper
Copper and nickel 45
red
white
T (copper, copper and nickel
NC
iron
Copper and nickel 18
red
grey
N (nickel chrome - nickel silicon silicon)
NX
Nickel chromium silicon
Nickel and silicon
red
grey
Conductor (2) compensation and compensation cable to use classification, grade and sheath color: see table 4
Table 4
Using the classification
Mark code
Tolerance level and sign
Sheath coloration
Regular grade
Precision level
Regular grade
Precision level
The Ann model
In general use
G
province
S
black
gray
blue
Heat with
H
black
gray
blue
Conductor (3) compensation and compensation cable thermoelectric properties and tolerance table: see table 5
Table 5
model
use
classification
℃ temperature range
The thermoelectric emfs tolerances mu V
Measure the end
Temperature ℃
Reciprocating resistance 20 ℃ length is 1 m not greater than Ω
Regular grade
Precision level
0.5mm2
1.0mm2
1.5mm2
2.5mm2
SC
G
0 ~ 100
Plus or minus 60 (plus or minus 5.0 ℃)
Plus or minus 30 (plus or minus 5.0 ℃)
1000
0.10
0.05
0.03
0.02
H
0 ~ 200

KCA
G
0 ~ 100
+ 100 (plus or minus 2.5 ℃)
Plus or minus 60 (plus or minus 1.5 ℃)
1000
1.40
0.70
0.47
0.28
H
0 ~ 200
900
KCB
G
0 ~ 100
900
1.04
0.70
0.47
0.28
KX
G
- 20 ~ 100
900
2.20
1.10
0.73
0.44
H
- 25 ~ 200
900
EX
G
- 20 ~ 100
+ 200 (plus or minus 2.5 ℃)
+ 120 (plus or minus 1.5 ℃)
500
2.50
1.25
0.83
0.50
H
- 25 ~ 200
500
JX
G
- 20 ~ 100
+ 140 (plus or minus 2.5 ℃)
+ 85 (plus or minus 1.5 ℃)
500
1.30
0.65
0.43
0.26
H
- 25 ~ 200
500
TX
G
- 20 ~ 100
Plus or minus 60 (plus or minus 1.0 ℃)
Plus or minus 30 (plus or minus 0.5 ℃)
300
1.04
0.52
0.35
0.21
H
- 25 ~ 200
+ 90 (plus or minus 1.5 ℃)
Plus or minus 48 (plus or minus 0.8 ℃)
300
NC
G
0 ~ 100
+ 100 (plus or minus 2.5 ℃)
Plus or minus 60 (plus or minus 1.5 ℃)
900
1.50
0.75
0.50
0.30
H
0 ~ 200
900
NX
G
- 20 ~ 100
900
2.86
1.43
0.95
0.57
H
- 25 ~ 200
900
(4) other performance indicators: see table 6
Table 6
project
Single bit
Performance indicators
PVC insulated
F46 insulation or F insulation
Insulation resistance (20 ℃) or greater
M, Ω km,
25
500
Voltage test
V/1min
1000
Flame retardant performance
By the supply and demand both sides according to the using condition of the compensation cable according to standard GB/T18380-2001 agreed

5, model, name: see table 7 ~ 8

Table 7 compensation conductor
Type no.
The name says
KX-VVPVC insulated and sheathed index K thermocouple with compensation lead
KX-VPVPVC insulated and sheathed wire braided shielding K dividing thermocouple with compensation conductor
KX-FFFluorine plastic insulation and sheath K dividing thermocouple with compensation lead
KX-FPFFluorine plastic insulated and sheathed wire braided shielding index K thermocouple with compensation conductor
KX-FV-105Fluorine plastic insulation heat 105 ℃ PVC sheathed index K thermocouple with compensation lead
KX-FPV-105Fluorine plastic insulated copper wire braided shielding heat 105 ℃ PVC sheathed index K thermocouple with compensation conductor
KX-HF4BPtfe insulation glass wool woven sheath K dividing thermocouple with compensation lead
KX-HF4PBPtfe insulated copper wire braided shielding glass wool weaving sheath index K thermocouple with compensation conductor
Note: (1) other model compensating conductor SC, KC, EX, JX, TX, NC, NX, etc., need to rewrite the model first, such as: the EX - VVP;
(2) shielding type: P: copper wire shielding, P1: tin silk screen;
(3) fluorine plastic insulation and sheath high temperature compensating conductor with fluorine plastic overall continuous extrusion, has the very good electronic water and acid and alkali resistant properties;
(4) (G) is commonly used in general grade and precision (S) and with heat (H) general grade and precision (S) compensation conductor should be indicated in the order.
Table 8 compensation cable
Type no.
The name says
KX-VVPVC insulated to ground PVC sheathed index K thermocouple compensating cable
KX-VPVPVC insulated twisted-pair copper wire braided shielding PVC sheathed K points degree of thermocouple compensating cable
KX-VPVPPVC insulated twisted-pair copper wire braided dividing points total shield PVC sheathed K thermocouple compensating cable
KX-VVPPVC insulated twisted-pair copper wire braided dividing total shield PVC sheathed K thermocouple compensating cable
KX-FFFluorine plastic insulation to ground fluorine plastic sheath index K thermocouple compensating cable
KX-FPFFluorine plastic insulation twisted-pair copper wire braided shielding fluorine plastic sheath K points of thermocouple compensating cable
KX-FPFPFluorine plastic insulation twisted-pair copper wire braided shielding dividing total shielding fluorine plastic sheath K thermocouple compensating cable
KX-FFPFluorine plastic insulation twisted-pair copper wire braided dividing total shielding fluorine plastic sheath K thermocouple compensating cable
KX-FV-105Fluorine plastic insulation to ground heat 105 ℃ PVC sheathed index K thermocouple compensating cable
KX-FPV-105Fluorine plastic insulation twisted-pair copper wire braided shielding heat 105 ℃ PVC sheathed index K thermocouple compensating cable
KX-FPVP-105Fluorine plastic insulation twisted-pair copper wire braided shielding total shielding heat 105 ℃ PVC sheathed index K thermocouple compensating cable
KX-FVP-105Fluorine plastic insulation twisted-pair copper wire braided total shielding heat 105 ℃ PVC sheathed index K thermocouple compensating cable
KX-HF4BPtfe insulation to ground glass wool woven sheath K dividing thermocouple compensating cable
KX-HF4PBPtfe insulation twisted-pair copper wire braided shielding glass wool woven jacket index K thermocouple with compensation cable shielding
KX-HF4PBPPtfe insulation twisted-pair copper wire braided shielding dividing total shielding glass wool woven sheath K thermocouple with compensation cable shielding
KX-HF4BPPtfe insulation twisted-pair copper wire braided dividing total shielding glass wool woven sheath K thermocouple with compensation cable shielding
Note: (1) other types of compensation cable SC, KC, EX, JX, TX, NC, NX, etc., need to rewrite the model first, such as: the EX - VPV;
(2) shielding type: P: copper wire shielding, P1: tin wire shielding, P3: aluminum/polyester composite membrane, P2: copper plastic composite film;
(3) fluorine plastic insulation and sheath high temperature compensating conductor with fluorine plastic overall continuous extrusion, has the very good electronic water and acid and alkali resistant properties.
(4) (G) is commonly used in general grade and precision (S) and with heat (G) general grade and precision compensation cable (S) indicated in the order.
(5) the Ann compensation cable need to be add "IA -" before the original model, such as: IA KX - VPVP;To be flame retardant compensation cable, should add "out" before the original model.
6, delivery requirements
According to the agreement to allow any length delivery, length measuring error of plus or minus 0.5%.
7, the order information
When placing order, be sure to indicate the product name, model, logarithmic, heat-resistant grade, block type, quantity, etc.


on aFluorine plastic insulation compensating cable
nextPVC insulated compensating cable
bottom.jpg
  • fax:021-51685578
  • mail:info@puguang.com
  • address:Zhabei District, Haining, Shanghai Road, No. 899, Changtai enterprise World Plaza, A building, 22 floors
link:BaiduSougou